Main /
StimulusDisplayThe current setting consists of the videoprojector as primary device and two CRT monitors as secondary devices. The image resolution is set to 1440 x 1050, with a refresh rate of 60 Hz. Below is the default setting for visual and audio stimulus display: Videoprojector: • primary display device
• 60 Hz refresh rate
• 1400 x 1050 resolution
• parameters settings:
menu Position/Size: "Through" (your image size will be adapted to its input resolution)
menu Picture:
* picture mode: manual
* contrast set to 30
* bright set to 0
* color set to 40
* tint set to 30
* color temp set to "user1"
* gamma set to "default"
Stimulation computer main display: • secondary display device
• 60 Hz refresh rate
• 1400 x 1050 resolution
Audio amplifier: • source set to CD
• sound intensity set to 45
• loudspeakers and audio amplifier are both connected to the stim pc (via splitter)
audio-visual synchronisation: • visual stimuli are visible on the projection screen about 33 milliseconds *after* the sound. This is due to the fact that 2 visual frames (16 ms x 2) are buffered by the projector. Adjust your timing accordingly if audiovisual synchronization is crucial.
|